PERGOLA VIVA · TECHNICAL GUIDE

Pergola and glass specifications, explained.

Understand the profiles, roof materials, glazing and controls behind the finished space. Use this guide alongside the product page to compare specifications and plan your project.

Explore the details

READING A GLASS UNIT

Three layers. One total.

Overall unit thickness24 mm
A calculation example. Safety treatment, coating and gas fill are specified separately for the selected system.

01 · Roof & profiles

Read the technical differences in a pergola quotation

Rail dimensions, fabric weight and motor brand are useful starting points. A meaningful comparison also considers section drawings, materials, drive components, connections and installation scope.

70 × 150 or 90 × 150 mm: what does the size tell you?These names describe a nominal outside section. Wall thickness, internal webs and mass per metre need separate information.

You may encounter rails labelled 70 × 150, 90 × 150 or 110 × 150 mm. Economy and premium are not shared technical classifications; the same outside size can appear in different series and section designs. Do not confuse rail dimensions with post dimensions or transfer one system’s structural assessment to another.

The two sections below are specification-reading examples, not a Pergola Viva series or standard equipment schedule. Their nominal names match, but the stated wall thickness and mass per metre differ. One marked thickness does not mean every wall in the section has that thickness.

70 × 150 or 90 × 150 mm: what does the size tell you?
Reading exampleNominal rail nameOutside dimensions in drawingStated thicknessCatalogue mass per metre
Section A90 × 150 mm91 × 150 mm2.5 mm5.217 kg/m
Section B90 × 150 mm91 × 150 mm1.8 mm4.129 kg/m
  • Outside dimensions describe the space occupied; the section drawing shows how material is distributed within it.
  • kg/m is the mass of one metre of profile. Greater mass alone does not prove a particular wind or snow capacity.
  • A code such as 6063 identifies the alloy; T5 or T6 describes the material treatment condition. Both belong in the technical description.
  • Structural suitability depends on section, material, span, supports and connections together.
Fabric weight, blackout and fire classification describe different propertiesOne weight figure cannot describe the complete performance of a fabric.

As a specification-reading example, 850 g/m² means that one square metre of fabric has a mass of 850 grams. It is not a thickness in millimetres. PVC coating, supporting textile, light transmission, tensile and tear properties are described separately.

Blackout fabric limits light transmission. Translucent, blackout and foam-layer fabrics can serve different needs; choosing the heaviest alone is not enough. A waterproof fabric also does not establish the performance of the completed roof with all its joints and drainage.

Fabric weight, blackout and fire classification describe different properties
Data-sheet itemWhat it describesWhat it does not establish alone
Fabric weight · g/m²Material mass per unit areaThickness, service life or thermal insulation value
Light transmission · %The proportion of light passing through the materialTemperature inside the complete space
Tensile / tear dataMaterial behaviour in a specified test and directionWind capacity of the complete pergola
Reaction-to-fire classA specific product within the stated test scopeFire resistance of the complete roof assembly
Care instructionsAppropriate cleaning and useSuitability for every chemical or pressure washing method
120 Nm and 120 W do not mean the same thingRead the full motor model, torque, speed, operating time and control system together.

As label-reading examples, 120 Nm states turning moment and 10 rpm states rotational speed. Electrical input power is expressed in watts; supply uses volts and hertz. These values are not interchangeable. Roof travel time also depends on the transmission ratio and travel distance.

The operating-time entry describes how long the motor may run under specified conditions. It does not mean the roof can operate continuously all day. This matters in frequently used cafés and restaurants. Mechanical or electronic limits describe how travel endpoints are set; neither term automatically establishes obstacle detection.

120 Nm and 120 W do not mean the same thing
Motor / control informationWhat should be clear in the scope
Model, torque and speedSuitability for the moving fabric, louvre or panel system
Supply, current and input powerCompatibility with electrical preparation and protection
Operating time and usage patternModel requirements between repeated commands
Limits and safety functionsFunctions actually included and how they operate
Remote, receiver and sensorsCompatible models and control zones
Power cuts and servicingAny manual facility, backup supply and access to components
Match performance figures to the proposed installationA document for fabric, profile or motor does not certify every aspect of the completed pergola.

If wind speed, snow load, drainage capacity or cycle count is quoted, check the model, dimensions and installation covered by that value. A result for a different span cannot automatically be transferred to your site. Review the test standard, report date, issuing body, specimen description and application limits together.

Water management follows the route from fabric or louvres through gutters and posts to the final outlet. Building junctions and anchoring substrates need separate attention. A sensor, a large profile or a waterproof material cannot replace those details.

Match performance figures to the proposed installation
Document / dataWhat it should match
Profile material documentationAlloy, temper and profile / batch identification
Fabric data sheetActual product code, colour / variant and applicable test method
Motor documentationInstalled model and compatible controller
System test / performance reportRoof model, dimensions, connections and conditions within its scope
Project calculation and fixing detailActual site, spans, supporting substrate and anchorage
Compare the same scope for the same spaceMake the reasons behind a price difference visible through the technical choices.

A quotation listing only area, motor brand and colour leaves important differences unresolved. Compare roof movement, profile series, fabric or panels, motor model, connections, drainage and installation scope together. Identical overall dimensions can still produce different post layouts, clear heights and open-roof areas.

When discussing your project with Pergola Viva, share its intended use, site photographs and approximate dimensions. We can assess the technical selection around your home or business, fixing conditions and additional systems.

  • Roof movement: retracting PVC fabric, louvres rotating in place, or panels retracting directly to the rear.
  • Layout: width, projection, clear height, posts and stacking zone.
  • Equipment: profile / series codes, fabric or panels, motor, controller and any sensors.
  • Installation: anchorage, secondary structure, building junctions, drainage and electrical preparation.
  • Commercial scope: glazing / screens, lighting, shipping, installation, maintenance and written warranty terms.

02 · Glass selection

Tempered glass, insulating units, solar control and argon.

Read five specifications together: glass composition, safety treatment, coating, cavity and gas fill. For vertical, sliding and folding systems, frame compatibility, hardware, joints and installation also matter.

Five separate specification choicesA glass unit can combine several of these features.
Five separate specification choices
SpecificationWhat it describesWhat to put in the quotation
Glass constructionA single pane or an insulating unit with a sealed cavity.The thickness of every pane and cavity.
Safety treatmentTempering, laminated construction or a compatible combination.The treatment of each pane and any interlayer.
CoatingLow-E for heat control; Solar Low-E for heat and solar control.Coating manufacturer, product code and composition-specific performance.
CavityThe sealed space separating the panes.Width in millimetres and edge system.
Gas fillAir or a specified gas in the sealed cavity.Gas type and the manufacturer’s declared fill information.
20 mm and 24 mm describe overall unit thicknessDifferent layers can add up to the same total.

These three compositions are arithmetic examples that explain how to read unit thickness. They do not establish model compatibility, safety treatment, coating or gas fill. The actual specification must be agreed for the selected system and recorded in the quotation.

20 mm and 24 mm describe overall unit thickness
Illustrative compositionOuter paneCavityInner paneTotal
Example A4 mm12 mm4 mm20 mm
Example B4 mm16 mm4 mm24 mm
Example C6 mm12 mm6 mm24 mm
  • 8 mm tempered glass describes the thickness of one pane.
  • A 24 mm insulating glass unit includes the panes and cavity in that total.
  • Overall thickness does not automatically mean tempered, coated or argon-filled glass.
Low-E, Solar Low-E and argonMatch thermal requirements with orientation and daylight needs.

Low-E coating helps reduce heat transfer. Solar Low-E also controls solar energy. When a product is marketed as comfort glass, specify the actual coating and composition so its function is clear.

Argon is a gas used in the sealed cavity of an insulating unit. It can improve thermal performance compared with air in a suitable, otherwise equivalent composition. Its contribution depends on the actual construction and fill; one percentage cannot represent every unit.

Tempering, laminated construction, coating and argon are separate choices. Combining them requires compatible glass processing and a suitable framing system.

Compare values with the same scopeA glass-unit value is not a whole-system value.
Compare values with the same scope
Value or featureWhat it helps assessWhat to check
Ug · glass thermal transmittanceHeat transfer through the glass unit.The actual composition and equivalent calculation or test conditions.
Whole-system thermal transmittanceThe glass together with frames, edges and joints.A glass Ug value cannot be assigned to the entire installed frontage.
Solar factor · gTotal solar energy admitted through the glazing.Orientation, shading and heating or cooling requirements.
Visible light transmittanceDaylight admitted through the glass.The selected coating and glass colour.
Acoustic performanceThe sound insulation of the specified glass or assembly.Composition, joints and test scope; argon alone is not an acoustic solution.
What your quotation should specifyMake the glass options directly comparable.
  • System and model name; single-pane or insulating-glass construction.
  • Outer pane / cavity / inner pane thicknesses and overall thickness.
  • Which pane is tempered or laminated.
  • Coating manufacturer and product code, where applicable; gas type and fill information.
  • Panel dimensions, compatible load-bearing hardware and clear opening.
  • Whether any performance document covers the glass or the complete system.
  • Cleaning, maintenance and separate warranty scopes for glass and mechanism.

03 · Installation

The site completes the specification.

Support, drainage, access and controls belong in the same layout.

Supporting substrate and anchorageCladding is different from the structure that receives the load.

Assess the concrete, steel, aluminium or existing structural element at each fixing location. Cladding, insulation and cavities cannot simply be assumed to carry the installation. Base plates, fasteners, edge distances and any secondary structure are considered together.

A wall-supported or freestanding layout is assessed against spans, post positions, circulation and the roof weight. Adding glazing or zip screens can affect the connections as well as the appearance.

The water route from roof to groundCollection, discharge and cleaning access form one plan.
  • Define the building junction, roof gutters, any drainage within posts and the final outlet.
  • Route discharge away from uncontrolled flow at doorways or neighbouring spaces.
  • For sliding-glass thresholds, coordinate floor levels, outward drainage and cleaning access.
  • Keep gutters and outlets clear of furniture, cladding and later landscaping.
  • Use the selected model according to its instructions for rain and other weather conditions.
Electrical and control preparationConsider roof, glass, screens and lighting together.

Agree the motor requirements, supply point, cable route and required protection with a competent installer. Connection boxes must suit the exposure and remain accessible for maintenance. Preserve access for motor replacement and controller servicing.

Where there are several roof modules or side systems, define which zones operate separately and which operate together. Explain remote channels, sensor commands and power-cut behaviour at handover. Do not assume every model has manual opening or backup power.

What to check at handoverReview appearance, movement, use and maintenance together.
What to check at handover
CheckDetail to review
LayoutAgreed dimensions, clear passage, posts, panel parking and roof collection zone.
Movement and controlOpening and closing, travel limits, control zones and installed safety functions.
Joints and drainageBuilding, floor and glazing junctions; a controlled review of gutters and outlets.
Use and careModel-specific weather instructions, cleaning, maintenance and service access.
DocumentsWritten work scope, installed component details, warranty and service-request process.

04 · Quotation scope

Ten details for a clear quotation.

Compare these items for the same dimensions and site conditions.

  1. Product family, model and the roof or glazing movement.
  2. Width, projection, overall height and usable clear opening.
  3. Profile codes, section drawings, wall thicknesses and connection layout.
  4. Fabric or louvre selection, material codes, colour and surface finish.
  5. Glass panes, overall unit, tempering/lamination, coating and any gas fill.
  6. Motor and control model, electrical preparation, lighting and sensors where included.
  7. Building and floor junctions, anchorage, drainage and secondary structure.
  8. Safe access for glass cleaning, motors and moving components.
  9. Freight, installation, site preparation, included and excluded work.
  10. Delivery plan, payment terms and component-specific warranty and service scope.

QUESTIONS & ANSWERS

Technical questions, answered.

The terms that make a quotation easier to understand.

Put the specification into your project.

Share your location, intended use and available dimensions. We will assess the roof, glazing and installation scope together.

Discuss your project